Central ATS Classic Inglês, 8 – 32 Zonas, 4 Áreas e 16 Portas, Cx. Metálica
- Integrated alarm & access control system for up to 64 zones, 4 areas & 64 doors
- Modular RS485 data bus with continuous polling of up to 16 RAS and 15 DGP
- PLC with 24 macro logic equations
- 255 freely programmable outputs
- Built-in PSTN dialer
Relance
Intruder Alarm System
The Advisor MASTER is a full-blown intruder alarm system with more than 79 different input types. A maximum of 64 zones (inputs) can be programmed to operate over 4 independent alarm systems (areas). Zones may be assigned to a specific area (offices, stores, etc.) or common to all (reception, canteen, etc.). Each area may have its separate RAS.
Integrated Access Control
All the ATS panels can control 16 up to 64 doors and allow users to disarm alarm areas as access is granted. All panels also feature the exclusive “3 times badging” to arm.
Complete Family
The Advisor MASTER is a family of 4 control panels that all share the same software, accessories & manuals and only differ by the database & enclosure sizes.
Modular RS-485 data bus
The Advisor MASTER communicates with up to 16 RAS’s & 15 DGP’s using the RS485 data bus. All remote devices on the bus are continuously polled to ensure correct operation and can be connected in star or loop configuration using the optional ATS1740 or ATS1742 interfaces.
Alarm reporting
The ATS panels are capable of reporting alarms and specified events using a variety of formats (SIA, XSIA, CID or voice messaging) via either the build-in PSTN dialer. In conjunction with the ATS1801 and ATS1809 a TCP/IP reporting connection can be established for the Interlogix network receiver. Up to 4 central stations with 2 phone numbers per CS give 8 possible reporting connections.
PLC flexibility
The Advisor MASTER offers a total of flexibility in programming up to 255 outputs through 24 macro logic equations.
Analogue Inputs
All the inputs of the ATS panels are analogue inputs, which enables the measurement of input loops resistance (in Ohms or Voltages) for diagnostic purposes. The inputs can be 2 or 4 state monitored with EOL resistors of 2k2, 4k7 or 10k Ohms. All the control panels can measure the voltage and current supplied to all the devices on the RS485 data bus and report back to the operator using TITAN Diagnostic.
European Software
The ATS control panels have the same software across Europe with different country default setting. This allows international customers to streamline their security equipment and promote common security procedures throughout their European operations.